Bridge Unit Motor Cover Removal; Bridge Unit Right Cover Removal; Sensor (Bridge Unit Media Entrance) Removal - Lexmark X940e Service Manual

Mfp finisher
Hide thumbs Also See for X940e:
Table of Contents

Advertisement

Bridge unit motor cover removal

1. Remove the bridge unit assembly. See
2. Remove the three screws securing the bridge unit motor unit (A) to the assembly.
3. Remove the bridge unit motor cover (A).
Note: When removing the bridge unit motor cover (A), the grounding strap (B) will become detached.
Replacement note: When replacing the bridge unit motor cover (A), ensure that the grounding strap (B) is
properly attached or jamming may occur.

Bridge unit right cover removal

1. Remove the bridge unit assembly. See
2. Remove two screws securing the bridge unit right cover (A) to the assembly.
3. Remove the bridge unit right cover (A).

Sensor (bridge unit media entrance) removal

1. Remove the bridge unit assembly. See
2. Place the bridge unit assembly upside down.
3. Remove the screw securing the bracket (A) to the bridge unit assembly (B).
4. Disconnect the connector from the sensor (bridge unit media entrance) (C).
"Bridge unit assembly removal" on page
"Bridge unit assembly removal" on page
"Bridge unit assembly removal" on page
7510-XXX
4-5.
4-5.
4-5.
4-11
Repair information

Advertisement

Table of Contents
loading

This manual is also suitable for:

X945e

Table of Contents