7510-XXX
Step
Check
3
Check the bridge unit drive motor for proper operation.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch Finisher Motor Tests.
4. Touch Bridge unit drive motor.
Does the above component operate properly?
4
Check the bridge unit drive motor for proper
connection.
Is the above component properly connected?
5
Perform a print test.
Does the error remain?
6
Perform a print test.
Does the error remain?

281.00 Sensor (bridge unit media exit) late jam

Step
Check
1
Check the bridge unit media transport rolls.
Are the bridge unit media transport rolls free of excess
wear and contamination?
2-12
MFP Finisher Service Manual
Caution: When performing motor tests,
ensure that all cover and door interlock
switches are overridden.
Yes
No
Go to step 5.
Go to step 4.
Replace the
Replace the
bridge unit drive
connection.
motor.
Go to
"Bridge
unit drive motor
removal" on
page
4-8.
Go to step 5.
Replace the
Problem solved.
bridge unit
interface card
assembly.
Go to
"Bridge
unit interface
card assembly
removal" on
page
4-114.
Go to step 6.
Replace the
Problem solved.
finisher controller
card assembly.
Go to
"Finisher
controller card
assembly
removal" on
page
4-115.
Yes
No
Go to step 2.
Clean or replace
the bridge unit
assembly.
Go to
unit assembly
removal" on
page
"Bridge
4-5.