7510-XXX
6. Disconnect the connector from the sensor (bridge unit top cover interlock) (A).
Bridge unit drive motor removal
1. Remove the bridge unit assembly. See
2. Remove the bridge unit motor cover. See
3. Remove the three screws securing the bracket (A) to the assembly.
4. Remove the bracket (A).
5. Remove the two screws securing the bridge unit drive motor (B) to the assembly.
6. Remove the bridge unit drive motor (B).
Note: When removing the bridge unit drive motor (B), the bridge unit exit/de-curler drive belt (C) will become
detached.
4-8
MFP Finisher Service Manual
"Bridge unit assembly removal" on page
"Bridge unit motor cover removal" on page
4-5.
4-11.