JRC JMR-92 Series Field Service Manual page 90

Marine radar equipment, ecdis conning display
Table of Contents

Advertisement

Label
Name
J53
PSU_CONT
Chapter 2 System Configuration
Table 2.4.8 PSU I/O specifications 3
Signal
Pin
Name
1
AC FAIL
2
DC EMPTY
3
FAN ALM
4
N_PWRGD
5
SG
6
SG
7
N_24V_ON
8
N_MTR_ON
9
N_MNU_ON
I/O
Specification
Open Collector
OUT
Output
Open Collector
OUT
Output
Open Collector
OUT
Output
Open Collector
OUT
Output
-
-
-
-
Open Collector
IN
Input
Open Collector
IN
Input
Open Collector
IN
Input
2-32
Detail
Logic level H (within
40ms) : AC IN is less
than 75Vac typ.
Logic level H (within
40ms) : DC IN is less
than 18Vdc typ.
Logic level H: The Fan
motor anomaly.
Logic level H: PSU has low
output voltage under output
anomaly such as
overvoltage, overcurrent or
inner temperature
anomaly.
It is enabled while
N_MTR_ON is L. If it is H,
N_PWRGD is forced to be
L except under inner
temperature anomaly.
-
-
Logic level L: 24Vdc
(CCU) ON
Logic level L:
ACOUT(L/N),
48Vdc(+,-), 24Vdc(M+,
M-), and 24Vdc(1A, 2A)
ON
Logic level L: 24Vdc
(MNU) ON

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents