JRC JMR-92 Series Field Service Manual page 677

Marine radar equipment, ecdis conning display
Table of Contents

Advertisement

If the W853 or W854 cable has been installed, remove the following connector and screw.
J839:
Using a flat head screwdriver, hold down the tab of the connector with a "P839"
stamp seal of W853/W854 and pull it out.
Screw at the lower right of the RIF board: Remove the screw (M3) and then disconnect
Next, disconnect the connection cable with the CCU, either the W841 or the W842, from the J831
connector. The W841/W842 cable can be disconnected by cutting off the cable-tie that fastens the
W841/W842 cable to the cable clamp of the JB first and pulling out the W841/W842 cable while
pressing down the tab of the P831 connector next.
Scanner units using the W853/W854 cable:
NKE-2254-6HS
NKE-2103-6/6HS
Chapter 4 Replacement procedure
the crimp terminal with "FG" stamp seal
W853/W854.
(JMR-9225-6XH, JMR-7225-6XH)
(JMR-9210-6X/6XH, JMR-7210-6X/6XH)
W853 / W854
W841 / W842
4-456
of
P839
FG
P831