If some number of CMH-2370s have been installed and connected to the same SENSOR LAN
UNIT NQE-2443, you should change IP address of each CMH-2370 by S3 setting. Refer to Table.
2.5.15.
CMH-2370 to be connected to the IAS (Integrated Automation System) or AMS (Alert
Management System) is set the operation mode: ALC (Alert LAN Converter). Also in this case, set
the IP address in refer to Table. 2.5.15.
The location of S3, refer to Fig. 2.5.5.
S3
Mode
Position
0
1
2
3
4
5
SLC
6
7
8
9
A
B
C
D
ALC
E
F
SFI:System Function ID of each IEC 61162 channel will also be changed depending on the IP
address.
Chapter 2 System Configuration
Fig. 2.5.4 Outline of S3
Table. 2.5.15 IP Address setting table
IEC61162-450
No.
Main LAN
172.16.60.107
SLC1
172.16.60.108
SLC2
172.16.60.109
SLC3
172.16.60.110
SLC4
172.16.60.111
SLC5
172.16.60.112
SLC6
172.16.60.113
SLC7
172.16.60.114
SLC8
172.16.60.115
SLC9
172.16.60.116
SLC10
172.16.60.117
SLC11
172.16.60.118
SLC12
172.16.60.119
ALC1
172.16.60.120
ALC2
172.16.60.121
ALC3
172.16.60.122
ALC4
Sub LAN
Main LAN
172.17.60.107
192.168.60.107
172.17.60.108
192.168.60.108
172.17.60.109
192.168.60.109
172.17.60.110
192.168.60.110
172.17.60.111
192.168.60.111
172.17.60.112
192.168.60.112
172.17.60.113
192.168.60.113
172.17.60.114
192.168.60.114
172.17.60.115
192.168.60.115
172.17.60.116
192.168.60.116
172.17.60.117
192.168.60.117
172.17.60.118
192.168.60.118
172.17.60.119
192.168.60.119
172.17.60.120
192.168.60.120
172.17.60.121
192.168.60.121
172.17.60.122
192.168.60.122
2-64
JRC Format
Sub LAN
192.168.61.107
192.168.61.108
192.168.61.109
192.168.61.110
192.168.61.111
192.168.61.112
192.168.61.113
192.168.61.114
192.168.61.115
192.168.61.116
192.168.61.117
192.168.61.118
192.168.61.119
192.168.61.120
192.168.61.121
192.168.61.122

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents