Contact Output
Connect the input of other equipment to the output port which is located on CMH-2370 in
JUNCTION BOX NQE-1143. The number of output ports on CMH-2370 is 8 ports allocated at
J8108. Terminal assign of J8108, refer to Table. 2.5.17
Fig. 2.5.9.
• See
about location of J8108 on CMH-2370.
• To configure the port, refer to
• Connect the cable shield to the hex spacer surrounded by the circle in the figure below.
(Recommended crimp terminals V5.5)
Chapter 2 System Configuration
Chapter 4 of Installation Manual
Table. 2.5.17 Terminal Assign of J8108
Terminal
J8107
Number
1
OUT1
2
RET1
3
OUT2
4
RET2
5
OUT3
6
RET3
7
OUT4
8
RET4
9
OUT5
10
RET5
11
OUT6
12
RET6
13
OUT7
14
RET7
15
OUT8
16
RET8
2-68
.
So that the braided shield is not
shorted to the power supply terminal
block, please insulate the cable and
fix with cable tie. Please put the Extra
length of the cable to the bottom of
the display unit so that the not
shorted to the UPS or SENSOR LAN
switch unit.