2.5.5. Settings for NDC-1590 Central Control
Unit: CCU
If it is not suggested from JRC office, this VGA monitor setting is not necessary. Wrong
monitor setting may lose video output.
Do NOT set the ID rotary switch to position "2" when a DVI monitor is / or both a DVI
monitor and a VGA monitor are connected to the CCU.
Wrong monitor setting may lose video output.
Settings for ONLY connection of the VGA monitor to CCU.
This section describes the video output setting that CCU has the only VGA monitor for its
display. A VGA monitor will be connected to J4025 (Analog RGB) on CCU.
1. Turn off the CCU power. Then, Set the ID rotary switch as follows.
2. Turn on the CCU power. Confirm that the VGA output displays correctly.
Table. 2.5.21 ID rotary switch settings for CCU NDC-1590
ID rotary switch settings
2
Other
( Factory default = 0 )
CCU NDC-1590
Description
Only the VGA monitor is connected to J4205
(RGB_OUT) on the CCU.
A DVI monitor is connected to J4101 (DVI_MNU)
on the CCU.
Or, both a DVI monitor and a VGA monitor are
connected to J4101 (DVI_MNU) and J4205
(RGB_OUT) respectively on the CCU.
2-75