JRC JMR-92 Series Field Service Manual page 804

Marine radar equipment, ecdis conning display
Table of Contents

Advertisement

6.6
Setting Up a Serial Port
Use the "Serial Port" dialog to verify the setting of the serial port of this equipment and perform the
initial setting. The status of ISW/MTR and Serial OPU can also be monitored.
6.6.1 Displaying the "Serial Port" dialog.
1.
Display the dialog of the Installation submenu.
2.
Select [System Configuration] in the 1st Classification pane and [Serial Port] in the
2nd Classification pane.
The "Serial Port" dialog is displayed in the Edit/Result pane.
Tab name
SLC1~4(M)/
SLC1~4(S)/
ALC1~4
[Diagnosis] lamp light colors
The [Diagnosis] lamp displays the diagnosis result as to whether the sentence regarding each serial
port is received and the status of ISW/MTR and Serial OPU.
Lit in red:
Data not received.
Lit in green:
Data is receiving.
Lit in orange: In diagnosis (before decision).
No color:
Serial port is disabled.
Note
 When the RADAR slave mode is active, the [Diagnosis] lamp of ISW/MTR is disabled.
 When the [Serial OPU] check box is set to Off after selecting [Service]-[Installation]-[System
Configuration]-[Subsystem Installation], the [Diagnosis] lamp of serial OPU is disabled.
Is displayed only if the SLC1 ~ 4 (S).
Refer to "For making SLC(Main) and
SLC(Sub) the same setup".