JRC JMR-92 Series Field Service Manual page 132

Marine radar equipment, ecdis conning display
Table of Contents

Advertisement

Current Signal Input
When Analog Sensors output specifications is Current, set as follows.
・Input Signal Range :4mA to 20mA
Channel
Fig. 2.5.11 Current input settings for CMJ-560 Analog Option Circuit
Chapter 2 System Configuration
Table. 2.5.20 Setting Table of Current Signal Input
Setting Table of Current Signal Input
Reference
1
TB2
TB6(4-20mA)
2
TB3
TB6(4-20mA)
3
TB4
TB6(4-20mA)
4
TB5
TB6(4-20mA)
Short the pins 2-3.
Refer to the above table.
Setting
Short-circuit the pins 2-3
Short-circuit the pins 1-5
Short-circuit the pins 2-3
Short-circuit the pins 2-6
Short-circuit the pins 2-3
Short-circuit the pins 3-7
Short-circuit the pins 2-3
Short-circuit the pins 4-8
Refer to the above table.
2-74
Short the pins.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents