Error List On Info Display Only - Barco SLM R12 Plus Service Manual

Table of Contents

Advertisement

8. Local Keypad & LCD Display
Info Display
LCD Display
- H
ERROR(-4111)
VOLTAGE ERROR
- H
ERROR(-4112)
VOLTAGE ERROR
- H
ERROR(-4113)
VOLTAGE ERROR
- H
ERROR(-4114)
VOLTAGE ERROR
- H
ERROR(-4115)
VOLTAGE ERROR
- t
ERROR(-5001)
DMD TEMPERATURE
- t
ERROR(-5002)
AMBIENT OVERTEMP
- t
ERROR(-6000)
TILT ERROR
8.4.2

Error List on INFO display Only

Error List
The first column of this table represents the two characters displayed on the information display and the second column the fault
description which is NOT displayed in the LCD display.
Image 8-7
Display fault analysis
Info
Error
Display
- c
2
I
C ERROR SCL Line
- d
I
2
C ERROR SDA Line
- H
"Hardware" ERROR
52
Error Description
Voltage +15V is too low
Voltage +30V is too low
Voltage +12V is too low
Voltage +5V is too low
Voltage +3V3 is too low
The temperature of one or more DMD's is out of range.
The ambient temperature is too high.
The projector is not correctly positioned.
Error Description
2
The I
C SCL line doesn't react (held down), so no I
is possible.
The I
2
C SDL line doesn't react (held down), so no I
is possible.
Indicates an error concerning the hardware. This can be:
incompatible hardware found
hardware failure
R5976820 SLM R12+ PERFORMER 08/03/2005
C
2
C communication
2
C communication

Advertisement

Table of Contents
loading

Table of Contents