8. Local Keypad & LCD Display
Info Display
LCD Display
- L
ERROR(-2001)
MAINS VOLTAGE TOO LOW
- L
ERROR(-2002)
LAMP START FAILED
- L
ERROR(-2003)
MAINS VOLTAGE TOO HIGH
- L
ERROR(-2004)
LAMP GONE OUT
- L
ERROR(-2040)
MAINS ERROR FROM LPS
- L
ERROR(-2101)
LAMP POWER SUPPLY
- L
ERROR(-2104)
LAMP POWER SUPPLY
- L
ERROR(-2124)
LAMP POWER SUPPLY
- L
ERROR(-21xx)
LAMP POWER SUPPLY
- L
ERROR(-2201)
START PC NOT OK
- L
ERROR(-2202)
START LPS NOT OK
- L
ERROR(-2203)
START BOOST NOT OK
- L
ERROR(-2206)
LAMP IGNITION FAILED
- L
ERROR(-2207)
LAMP VOLTAGE OUT RANGE
- L
ERROR(-2208)
LAMP POWER OUT RANGE
- L
ERROR(-2209)
OVERTEMP IN LPS
- L
ERROR(-2210)
HTSNK OVERTEMP LPS
- L
ERROR(-2211)
AMBIENT OVERTEMP LPS
- L
ERROR(-2212)
FAN ERROR LPS
- L
ERROR(-2401)
LAMP POWER SUPPLY
48
Error Description
Mains voltage lower than minimum specified mains voltage.
Unable to start the lamp.
Mains voltage higher than maximum specified mains voltage.
Lamp shut down, unknown error
There is no mains supply from LPS to SMPS
LPS with I
2
C slave address 0x20: Fuse F100 is blown.
LPS with I
2
C slave address 0x20: Mains voltage too low; must be
>180Vrms.
2
LPS with I
C slave address 0x20: Error in LPS power circuits.
LPS with I
2
C slave address 0x20: Unknown LPS error
LPS with I
2
C slave address 0x20: Start-up of the PFC module failed.
LPS with I
2
C slave address 0x20: Start-up of the LPS module failed.
LPS with I
2
C slave address 0x20: Start-up of the BOOST module failed.
2
LPS with I
C slave address 0x20: Ignition of the lamp failed.
LPS with I
2
C slave address 0x20: The voltage at the lamp is too high.
LPS with I
2
C slave address 0x20: The power at the lamp is too high.
LPS with I
2
C slave address 0x20: Temperature in LPS is too high.
2
LPS with I
C slave address 0x20: Heatsink temperature in LPS is too
high.
LPS with I
2
C slave address 0x20: Ambient Temperature in LPS is too
high.
LPS with I
2
C slave address 0x20: Fan error.
LPS with I
2
C slave address 0x22: Fuse F100 has blown up.