Status Conditions / Fault Analysis - Barco SLM R12 Plus Service Manual

Table of Contents

Advertisement

D602
Q602
Q603
Q600
Q601
Image 21-6
Component location on board/2

21.5 Status Conditions / Fault Analysis

Introduction
The load condition of the programmable logic's is indicated by means of a Red LED, linked to the respective logic IC. Non lightning
of a LED indicates correct loaded IC. These LED's, mounted on the rear of the PMP module, become visible when the dummy plate,
covering the second SDI Input, or the mounted second SDI module itself is removed.
Location of the LEDs
Image 21-7
Location of the LEDs
LED Ref.
IC Ref.
D10
Logics on Input Selector
D100
Altera IC100
D200
Xilinx IC205
R5976820 SLM R12+ PERFORMER 08/03/2005
21. Pixel Map Processor Module R764115
D652
Q650
Q652
IC650
D200
D100
D300
Descriprion
LED On: logics on input selector configured
LED On: Altera configured
LED On: Xilinx configured
Status Condition PMP
D400
D500
D10
161