Connector: J603 Controls
Pin Name
GND
GND

15.8 Adjustments on Board

Location of the Adjustment Controls
LPS-X In/Out/3 R7632113
Lamp Current Sense Adj.
P340
Image 15-15
Adjustment controls on LPS
Special Equipment is required for the alignment of the different adjustment controls on the Lamp Power
Supply. For that reason, NEVER attempt to re-adjust the different adjustment controls in order to maintain the
factory-preset performances and to prevent damage to other connected electrical circuits.
R5976820 SLM R12+ PERFORMER 08/03/2005
Pin No
In/Out
-
11
-
12
+380VM Adj. P420
15. Lamp Power Supply R7633705
Description
Secondary Ground
Secondary Ground
LPS-X Processing/5 R7632105
PFC Out Sense Adj.
P310
Heatsink LPS Temp Sense Adj.
WARNING
Signal
Heatsink PFC Temp Sense adj.
P320
Power Adj.
P260
P330
123