27.5.3.2 Disconnecting the formatter and DMD connections
Necessary tools
•
Torx® driver TX10
•
Pair of wire-cutters
Disconnect the formatter power connections
1. Turn out both screws (1) fixing the ground leads of the formatter supply cables to the formatter interface board.
1
Image 27-75
Formatter supply connections
2. Pull out the formatter power connectors (2, 3 and 4).
2
green formatter power connector
3
blue formatter power connector
4
red formatter power connector
3. Cut the white wire tires.
Disconnect the formatter signal connections
1. Turn out both screws (5) fixing the ground leads of the formatter signal cables to the formatter interface board.
5
6
Image 27-76
Formatter signal connections
2. Pull out the formatter signal connectors (7, 8 and 9)
R5976820 SLM R12+ PERFORMER 08/03/2005
3
4
2
7
8
1
5
27. Maintenance