27. Maintenance
27.3.2 Introduction
27.3.2.1 Content of the kit
Content of the kit
The lamp kit consists in a lamp housing, Xenon lamp included. That means that the lamp position is factory calibrated following the
X- ,Y- and Z-axis. When observing a decrease in light output during the run time of the lamp, ONLY a realignment following the
Z-axis can solve the light output decrease.
B
Image 27-20
Spacers lock nut removal
Only for transport purposes, the 3 lamp housing fixation spacers (A) are fixed to the lamp casing frame by a
lock nut M5 (B). Always remove the lock nuts before inserting the lamp housing into the projector
27.3.3 Removing the old lamp
27.3.3.1 Access to the Lamp Unit.
What has to be done
To access the lamp casing, a side panel has to be removed.
Necessary tools
A flatblade screwdriver of 5 mm
Removing the side panel
1. Turn with a screwdriver the side panel lock screw (A) a quarter turn counter clockwise.
192
A
R5976820 SLM R12+ PERFORMER 08/03/2005