27. Maintenance
A
Image 27-44
Removal input panel
2. Keep the input panel by the provided handles and pull it backwards to remove.
Now, the backplane (board at he bottom) is accessible on which the cable plug of the mentioned Fans are plugged in.
3. Pull the two plugs J30 & J31 out their respective socket.
J30
Image 27-45
Fan disconnection
The cooling Fan for the blue DMD and the Prism are switched off.
4. Reinstall the Input panel and tighten the fixation screws.

27.4.2.3 Temporarily Replacement of the Air Channel

Overview
Removal of the Air Channel
Installation of the Service Air Channel (Part of the kit)
Why to replace the air channel
Between the Green DMD and the air channel there is lack of space to allow loosening the Green DMD support. Installing the service
air channel, part of the kit, provides the necessary space.