Barco SLM R12 Plus Service Manual page 51

Table of Contents

Advertisement

Info Display
LCD Display
- L
ERROR(-2404)
LAMP POWER SUPPLY
- L
ERROR(-2424)
LAMP POWER SUPPLY
- L
ERROR(-24xx)
LAMP POWER SUPPLY
- L
ERROR(-2501)
START PFC NOT OK
- L
ERROR(-2502)
START LPS NOT OK
- L
ERROR(-2503)
START BOOST NOT OK
- L
ERROR(-2506)
LAMP IGNITION FAILED
- L
ERROR(-2507)
LAMP VOLTAGE OUT RANGE
- L
ERROR(-2508)
LAMP POWER OUT RANGE
- L
ERROR(-2509)
OVERTEMP IN LPS
- L
ERROR(-2510)
HTSNK OVERTEMP LPS
- L
ERROR(-2511)
AMBIENT OVERTEMP LPS
- L
ERROR(-2512)
FAN ERROR LPS
- L
ERROR(-2701)
LAMP POWER SUPPLY
- L
ERROR(-2704)
LAMP POWER SUPPLY
- L
ERROR(-2723)
LAMP POWER SUPPLY
- L
ERROR(-2724)
LAMP POWER SUPPLY
- L
ERROR(-2725)
LAMP POWER SUPPLY
- L
ERROR(-2726)
LAMP POWER SUPPLY
- L
ERROR(-2727)
LAMP POWER SUPPLY
R5976820 SLM R12+ PERFORMER 08/03/2005
Error Description
LPS with I
2
C slave address 0x22: Mains voltage too low; must be
>180Vrms.
LPS with I
2
C slave address 0x22: Error in LPS power circuits.
LPS with I
2
C slave address 0x22: Unknown LPS error.
2
LPS with I
C slave address 0x22: Start-up of the PFC module failed.
LPS with I
2
C slave address 0x22: Start-up of the LPS module failed.
LPS with I
2
C slave address 0x22: Start-up of the BOOST module failed.
LPS with I
2
C slave address 0x22: Ignition of the lamp failed.
2
LPS with I
C slave address 0x22: The voltage at the lamp is too high.
LPS with I
2
C slave address 0x22: The power at the lamp is too high.
LPS with I
2
C slave address 0x22: Temperature in LPS is too high.
LPS with I
2
C slave address 0x22: Heatsink temperature in LPS is too
high.
LPS with I
2
C slave address 0x22: Ambient temperature in LPS is too
high.
2
LPS with I
C slave address 0x22: Fan error.
LPS with I
2
C slave address 0x28: Fuse F100 has blown up.
LPS with I
2
C slave address 0x28: Mains voltage too low; must be
>180Vrms.
LPS with I
2
C slave address 0x28: Error in LPS low voltage circuits.
2
LPS with I
C slave address 0x28: Error in LPS power circuits.
LPS with I
2
C slave address 0x28: Lamp has gone out and LPS still
running.
LPS with I
2
C slave address 0x28: Lamp output short-circuited.
LPS with I
2
C slave address 0x28: Output power out of range.
8. Local Keypad & LCD Display