Licensable Cartridge Slots (Storage And I/O) Per Model; Library Configurations - IBM System Storage TS3310 Setup And Operator Manual

Tape library
Hide thumbs Also See for System Storage TS3310:
Table of Contents

Advertisement

To enter a Capacity Expansion license key:
When the license key is entered, the total number of available slots in the library
increases. To verify that the number of slots did increase:
Path Failover (Feature Code 1682)
The Path Failover feature includes license keys for activating control path failover
and data path failover.
Control Path Failover
A control path is a logical path into the library through which a server sends
standard SCSI Medium Changer commands to control the logical library.
Additional control paths reduce the possibility that failure in one control path will
cause the entire library to be unavailable. Use of the control path failover feature
further reduces that possibility. For more information, see "Using Multiple Control
Paths" on page 2-2).
1-10
TS3310 Tape Library Setup and Operator Guide
From the Operator Panel: Setup → License
v From the Operator Panel, view the Capacity View home screen.
v From the Web User Interface: Monitor System → System Summary
Table 1-4. Licensable cartridge slots (storage and I/O) per model
Number of
Library
Available I/O
Configuration
Station Slots*
5U library
(control
6
module)
14U library
6 / 12 / 18
(control
module + 9U
expansion
module)
6 / 12 / 18
*The I/O station, in the 9U expansion module, contains 12 slots which can be configured
as either I/O or storage slots. If the 9U expansion module I/O slots are configured as I/O,
the control module slots can be configured as storage slots.
**The number of available I/O and storage slots listed in the table above are adjusted for
the ten unusable slots in each configuration. The number of physical slots is always ten
more than the number of licensable slots, because the bottom ten storage slots in a library
are not accessible due to space restrictions which limits the movement of the Picker. These
ten slots become available along with 36 slots in an expansion module when an expansion
module is added to the library.
Number of
Accessible
Total Slots**
Storage Slots
30
76 / 70 / 64
122 / 116 / 110
Capacity
Expansion
License Keys
required for...
no license key
36
required
no license key
82
required
1 license key
required (to
128
enable the full
capacity of a 14U
library)

Advertisement

Table of Contents
loading

Table of Contents