IBM System Storage TS3310 Setup And Operator Manual page 249

Tape library
Hide thumbs Also See for System Storage TS3310:
Table of Contents

Advertisement

Table C-2. LTO Tape Drive Sense Data (continued)
Byte
7
12–13
Additional Sense Code (ASC)
Additional Sense Code Qualifier (ASCQ)
Byte 12
Byte 13
ASC
ASCQ
00
00 - No additional sense — The flags in the sense data indicate the reason for
00
01 - Filemark detected — A Read or Space command terminated early due to an FM
00
02 - EOM — A Write or Write File Marks command failed because the physical
00
04 - BOM — A space command ended at Beginning of Tape
00
05 - EOD — Read or Space command terminated early
00
16 - Operation in progress
04
00 - Cause not reportable — A cartridge is present in the drive, but it is in the
04
01 - Becoming Ready — A media access command was received during a
04
02 - Initializing Command Required — A cartridge is present in the drive, but is not
04
03 - Manual Intervention Required — A cartridge is present in the drive but could
04
12 - Logical Unit Not Ready, Offline
08
01 - Logical Unit Communication Failure
09
00 - Track Following Error (Servo)
0C
00 - Write Error — A Write operation has failed. This is probably due to bad
11
00 - Unrecovered Read Error — A Read operation failed. This is probably due
14
00 - Recorded Entity Not Found — A space or Locate command failed because
14
03 - End Of Data not found — A Read type operation failed because a format
17
01 - Recovered Data with Retries
1A
00 - Parameter list length error — The amount of parameter data sent is incorrect
20
00 - Invalid Command Operation Code — The Operation Code in the command
24
00 - Invalid field in CDB — An invalid field has been detected in a
25
00 - LUN not supported — The command was addressed to a non-existent
26
00 - Invalid Field in Parameter List — An invalid field has been detected in the
27
00 - Write Protect — A Write type operation has been requested on a cartridge which
28
00 - Not Ready to Ready Transition — A cartridge has been loaded successfully into
28
01 - Import or Export Element Accessed
29
00 - Reset — The drive has powered on, received a reset signal or a bus device
29
04 - Device Internal Reset
(Continued on next page)
6
5
the command failure
The FM flag is set.
end of tape was encountered, or a Read or Space command encountered EOM
The EOM flag is set
The EOM bit is also set
because End of Data was encountered
process of being unloaded
front panel initiated load or an immediate reported load command
logically loaded. A Load command is required
not be loaded or unloaded without manual intervention
media, but may be hardware related
to bad media, but may be hardware related
a format violation prevented the target from being found.
violation related to a missing EOD data set
was not a valid Operation Code
Command Descriptor Block
logical unit number
data sent during the data phase
has been write protected
the drive and is now ready to be accessed
reset signal since the initiator last accessed it
Bit Address or Name
4
3
2
1
Appendix C. Sense Data
0
C-9

Advertisement

Table of Contents
loading

Table of Contents