T033: Drive Tapealert Flag 3 - Hard Read Or Write Error; T034: Drive Tapealert Flag 4 - Media - IBM System Storage TS3310 Setup And Operator Manual

Tape library
Hide thumbs Also See for System Storage TS3310:
Table of Contents

Advertisement

Possible CRU Replacements
Possible FRU Replacements
Resolution

T033: Drive TapeAlert Flag 3 - Hard read or write error

Description
Detection Scenarios
Root Causes
Possible CRU Replacements
Resolution

T034: Drive TapeAlert Flag 4 - Media

Description
Detection Scenarios
Root Causes
Possible CRU Replacements
Library Control Blade
v I/O Station Lock
v Picker
v Cable Spool
v Enclosure
Perform the following:
v "DR011: I/E (I/O Station) Lock Diagnostic (a Library
Verify Test)" on page 10-33
v Before replacing a library component or contacting IBM
Technical Support, refer to "Diagnosing a Problem" on
page 9-3 for additional diagnostic procedures.
System determines that the drive has issued a TapeAlert 3
indicating an unrecoverable read, write or positioning error.
Tape drive issues a Tape Alert 3 which is recognized by the
library during the continuous 4 second polling cycle of
drive status.
Drive has determined that there is a problem per its
internal algorithms.
v Cartridge
v Tape Drive
If the cartridge is managed by a host application, export
the cartridge via the host application.
If the cartridge is managed by the library, perform the
following:
v Remove the suspect cartridge (see "Exporting a Data
Cartridge" on page 7-15 or "Exporting a Cleaning
Cartridge" on page 7-16).
v Import a new cartridge (see "Importing Data Cartridges"
on page 7-15 or "Importing a Cleaning Cartridge" on
page 7-16).
System determines that the drive has issued a TapeAlert 4
indicating an unrecoverable read, write or positioning error
that the drive specifically isolates to a the media.
Tape drive issues a TapeAlert 4 which is recognized by the
library during the continuous four second polling cycle of
drive status.
Drive has determined that there is a problem per its
internal algorithms.
Tape Cartridge
Chapter 10. Service Action Tickets (Txxx) and Diagnostic Resolutions (DRxxx)