T017: Invalid storage or I/O position
Description
Detection Scenarios
Root Causes
Possible FRU Replacements
Resolution
T018: Invalid Drive Position
Description
Detection Scenarios
Root Causes
Possible CRU Replacements
Possible FRU Replacements
Resolution
T019: Cannot calibrate drive, motion OK
Description
10-10
TS3310 Tape Library Setup and Operator Guide
Calibration completes and the coordinates of each storage
and I/O element are calculated. The calculated values are
determined to be outside travel limits that have been
established for the robot.
Calculated element positions fail validity check against
travel limits.
1. Calibration targets not in position.
2. Calibration sensor detects edges but is not correctly
finding calibration target edges.
v Fiducial targets
v Y Motor
v Y-axis Assembly
v Cable Spool
v Picker Assembly
v Enclosure
Before contact IBM Technical Support, refer to "Diagnosing
a Problem" on page 9-3 for additional diagnostic
procedures.
Calibration completes and the coordinates of each drive are
calculated. The calculated values are determined to be
outside travel limits that have been established for the
robot.
Calculated element positions fail validity check against
travel limits.
1. Drive calibration target is not in position.
2. Calibration sensor detects edges but is not correctly
finding calibration target edges.
Drive Sled
v Y Motor
v Y-axis Assembly
v Picker Assembly
v Cable Spool
v Enclosure
Before replacing a library component or contact IBM
Technical Support, refer to "Diagnosing a Problem" on
page 9-3 for additional diagnostic procedures.
System electrically detects a drive and is able to scan the
bar code label but cannot successfully calibrate the position
of the drive. The calibration search pattern completes
successfully.