Table B-1. TapeAlert Flags Supported by the Ultrium Tape Drive (continued)
Flag
Number
Flag
22
Expired clean
23
Invalid cleaning tape
30
Hardware A
31
Hardware B
32
Interface
33
Eject media
34
Download fail
36
Drive temperature
37
Drive voltage
39
Diagnostics required
51
Tape directory invalid at
unload
52
Tape system area write
failure
53
Tape system area read
failure
Description
Set when the tape drive detects a
cleaning cartridge that has expired.
Set when the drive expects a
cleaning cartridge and the loaded
cartridge is not a cleaning cartridge.
Set when a hardware failure occurs
that requires that you reset the tape
drive to recover.
Set when the tape drive fails its
internal Power-On Self Tests.
Set when the tape drive detects a
problem with the SCSI, Fibre
Channel, or RS-422 interface.
Set when a failure occurs that
requires you to unload the cartridge
from the drive.
Set when an FMR image is
unsuccessfully downloaded to the
tape drive through the SCSI or Fibre
Channel interface.
Set when the drive's temperature
sensor indicates that the drive's
temperature is exceeding the
recommended temperature of the
library.
Set when the drive detects that the
externally supplied voltages are
either approaching the specified
voltage limits or are outside the
voltage limits (see "Specifications"
on page 1-15).
Set when the drive detects a failure
that requires diagnostics for
isolation.
Set when the tape directory on the
tape cartridge that was previously
unloaded is corrupted. The
file-search performance is degraded.
Set when the tape cartridge that was
previously unloaded could not write
its system area successfully.
Set when the tape system area could
not be read successfully at load time.
Action Required
Replace the cleaning cartridge.
Use a valid cleaning cartridge.
If resetting the drive does not
recover the error, note the error code
on the single-character display and
see Drive Error Codes and Messages
for the appropriate instructions.
Note the error code on the
single-character display and see
Drive Error Codes and Messages for
the appropriate instructions.
Locate Error Code 8 or 9 in Drive
Error Codes and Messages
Unload the tape cartridge, then
reinsert it and restart the operation.
Ensure that it is the correct FMR
image. Download the FMR image
again.
See Error Code 1 in Drive Error
Codes and Messages
See Error Code 2 in Drive Error
Codes and Messages
See Error Code 6 in Drive Error
Codes and Messages
Use your backup software to rebuild
the tape directory by reading all the
data.
Copy the data to another tape
cartridge, then discard the old
cartridge.
Copy the data to another tape
cartridge, then discard the old
cartridge.
Appendix B. TapeAlert Flags
B-3