Powerhead Installation - BRP EVINRUDE E-TEC 115 HP 2011 Service Manual

Table of Contents

Advertisement

Installation
Place mount assemblies in position, with flats fac-
ing away from each other.
Apply Moly Lube to all sides of retainer and install
between mounts.
Install the retainer screw and tighten to a torque of
15 to 20 ft. lbs. (20 to 27 N·m).
1. Mount retainer screw
POWERHEAD
INSTALLATION
Apply Permatex No. 2 to both sides of a new base
gasket as shown. Install gasket on adapter. To
ensure proper sealing, mating surfaces must be
clean and dry.
005310
1. Apply sealant to exhaust housing (V4)
2. Apply sealant to both sides of gasket
IMPORTANT:
interchangeable. Be sure to use the correct part.
Coat the driveshaft splines with Moly Lube. Do not
apply lubricant to end of driveshaft.
1
Use Lifting Fixture, P/N 342672, and hoist to
slowly lower powerhead onto exhaust housing. If
necessary, rotate flywheel in a clockwise direction
to align crankshaft and driveshaft splines.
005309
POWERHEAD

POWERHEAD INSTALLATION

1
2
V4 and V6 base gaskets are NOT
007155
10
005276
219