Electric Start Tests - BRP EVINRUDE E-TEC 115 HP 2011 Service Manual

Table of Contents

Advertisement

ELECTRICAL AND IGNITION

ELECTRIC START TESTS

Key Switch, START Position
Key switch START:
Switches 12 V to terminal "S" of key switch and
to the neutral safety switch (in remote control).
A closed neutral safety switch provides 12 V to
the engine wire harness yellow/red wire and
terminal 26 of EMM J-1A connector.
EMM grounds brown/white wire to activate sole-
noid.
M
A
4
5
6
3
2
1
1. Ignition switch, START position – Continuity
between terminals "B" and "A"; "B" and "S"
2. Terminal "S", 12 V
3. Neutral safety switch
100
1
B
M
C
S
B
C
M
A
2
3
000691R
ELECTRIC START TESTS
Starter Solenoid Test
Disconnect the B+ (POS) battery cable at the bat-
tery.
IMPORTANT:
noid terminals before proceeding with this test.
Use a digital multimeter to measure resistance.
Put one meter lead on the starter positive (+)
cable terminal and the other lead on the battery
positive (+) cable terminal:
Meter must not show continuity (high reading).
If meter shows continuity (low reading), replace
the solenoid.
1
M
S
2
1. "A" terminal, B+ (purple)
2. "B" terminal, NEG (brown/white)
3. Starter positive (+) cable terminal
4. Battery positive cable (B+) terminal
Apply B+ to terminal "A" of solenoid and ground
(NEG) to terminal "B" of solenoid. Measure resis-
tance between the starter positive (+) cable termi-
nal and the positive battery (+) cable terminal.
The solenoid must close with an audible click.
Meter must show continuity (low reading).
If meter shows no continuity (high reading),
replace the solenoid.
After re-installing the solenoid, coat all wires and
terminals with Black Neoprene Dip.
Disconnect all wiring from sole-
4
3
004121

Advertisement