Terminal Removal
A tab on the back side of the terminal engages a
shoulder in the connector housing to hold the ter-
minal in place. The terminal is removed by releas-
ing the tab and then pushing the terminal and wire
through connector housing.
Insert a thin tool into the connector above the ter-
minal to release tab.
1. Tab
Terminal Installation
Install wire gasket on wires and feed wires
through the correct terminal position of the con-
nector housing. Terminal is crimped onto wire and
then pulled back into connector housing until lock-
ing tab engages and terminal is seated.
1
Crimping Terminals
Strip insulation back 3/16 in. (5 mm). Position end
of wire strands in terminal past the wire crimp area
and the end of insulation in the insulation crimp
DRC5940a
area of the terminal.
Capture all wire strands in crimp; leave no loose
strands. Crimp wire and insulation securely using
crimping pliers.