N-3 Format Assign
N-3-1
Symbol Number
Symbol Number refers to the number of the symbol to which output formatting will
Definition:
apply. For example, if you wish to enable user-defined formatting to symbol # 2 in a
multisymbol read cycle, you would send the command <K742,2,1>.
Note that the number of symbols may exceed the format capabilities.
Serial Cmd: <K742,symbol number,status>
1 to 400
Options:
1 = Formatted output status for symbol # 1.
2 = Formatted output status for symbol # 2.
...(Cont.)
400 = Formatted output status for symbol # 400.
N-3-2
Status
Status refers to the user-defined formatting of a selected symbol position in the read
Definition:
cycle result. Note that there is also a global formatting "enable" command that must be
set for the formatting to be applied.
Serial Cmd: <K742,symbol number,status>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled (Assigns parameters to specified symbol.)