Image Storage (Continued from Previous Page)
Stored Image Type allows you to configure which images are stored to the destination device. Options are:
• Good Read: Saves image(s) where the decoder reports a good read.
• No Read: Saves image(s) where the decoder does not report a good read (default).
• Good Read and No Read: Save both Good Read and No Read decoder reports.
• Match: Save reports satisfying Match criteria.
• Mismatch: Save reports satisfying Mismatch criteria.
• Match and Mismatch: Save reports satisfying both Match and Mismatch criteria.
• All: Save All reports.
Storage Mode represents which image or images are stored. Options are:
• First Image in a Read Cycle: Save first image that qualifies the Stored Image Type (default).
• All Images in a Read Cycle: Save all images that qualify the Stored Image Type.
Image File Format allows you to select which file format to apply to the saved image. Options are:
• PNG – High Resolution: Save images using .png format (default).
• JPG – Low Resolution: Save images using .jpg format.
• BMP – Direct Raw: Save images using .bmp format.
Image Quality is a sliding scale between 1% and 100%, where the higher the image quality, the more
space is required to store the image. The default setting is 90%.
Image Scale represents the amount of data compression applied to the stored image. Images with a
lower compression ratio require more storage space. Options are:
• 1:1 – No data compression applied. Full image (default).
• 2:1 – Image compressed by 50%.
• 4:1 – Image compressed by 75%.
• 8:1 – Image compressed by 88%.
File Save Options allow you to decide which type of report to save. Options are:
• Image: Saves images (default).
• Read Cycle Report: Saves cycle reports.
• Image and Read Cycle Report: Saves images and cycle reports.
Image Storage Location is where images and reports are stored. Options are:
• RAM (Volatile Memory): Images and cycle reports are saved to internal RAM drive (default).
• Remote (FTP): Images and cycle reports are saved to a remote FTP-connected device.
When the Image Storage Location setting is configured as RAM, all information is saved to a RAM
drive onboard the camera. This drive is volatile and all data is lost when the unit resets.