H-4 Read Duration Output
Usage:
Definition:
H-4-1
Read Duration Output Mode
Serial Cmd:
Default:
Options:
• Important: To measure the entire read cycle when in External Level trigger mode, set When to Output Symbol Data
to End of Read Cycle.
This output can measure over 49 days' worth of duration; if exceeded, the "OVERFLOW" message will
be output in place of the duration.
H-4-2
Read Duration Output Separator
Definition:
Serial Cmd:
Default:
Options:
V440-F C-Mount Code Reader User Manual
Useful in evaluating actual read cycle timing results, especially when
initially setting up an application to determine maximum line speed
(obtainable based on spacing between symbols.)
When enabled the duration of the read cycle (in milliseconds) is appended
to the symbol data.
The read duration is the time from the beginning of the read cycle until data
is output.
<K706,status,separator>
Disabled
0 = Disabled
1 = Enabled
User defined character that separates the symbol information from the

Read Duration Output.

<K706,status,separator>
[space character]
Any ASCII character.
Appendices
H
H-7