Omron V440-F User Manual page 363

C-mount code reader
Table of Contents

Advertisement

Appendices
 Fixed Pattern Damage Threshold
Usage:
Definition:
Serial Cmd:
Default:
Options:
 Axial Non-uniformity
Usage:
Definition:
Serial Cmd:
Default:
Options:
 Axial Non-uniformity Threshold
Usage:
Serial Cmd:
Default:
Options:
 Grid Non-uniformity
Usage:
Definition:
Serial Cmd:
Default:
Options:
H-28
Sets the threshold for driving the output.
Conforms to ISO/IEC 29158 symbol quality grading (A,B,C,D).
<K890, output on overall grade, overall grade threshold, cell contrast, cell
contrast threshold, cell modulation, cell modulation threshold, fixed pattern
damage, fixed pattern damage threshold, axial non-uniformity, axial non-
uniformity threshold, grid non-uniformity, grid non-uniformity threshold,
unused ECC, unused ECC threshold>
Grade B
0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A
Lets the user know if symbol quality is less than acceptable.
If enabled, drives Output if grade is under Axial Non-uniformity Threshold.
<K890, output on overall grade, overall grade threshold, cell contrast, cell
contrast threshold, cell modulation, cell modulation threshold, fixed pattern
damage, fixed pattern damage threshold, axial non-uniformity, axial non-
uniformity threshold, grid non-uniformity, grid non-uniformity threshold,
unused ECC, unused ECC threshold>
Disabled
0 = Disabled
Sets the threshold for driving the output.
<K890, output on overall grade, overall grade threshold, cell contrast, cell
Definition: Conforms to ISO/IEC 29158 symbol quality grading (A,B,C,D).
contrast threshold, cell modulation, cell modulation threshold, fixed pattern
damage, fixed pattern damage threshold, axial non-uniformity, axial non-
uniformity threshold, grid non-uniformity, grid non-uniformity threshold,
unused ECC, unused ECC threshold>
Grade B
0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A
Lets the user know if symbol quality is less than acceptable.
If enabled, drives Output if grade is under Grid Non-uniformity Threshold.
<K890, output on overall grade, overall grade threshold, cell contrast, cell
contrast threshold, cell modulation, cell modulation threshold, fixed pattern
damage, fixed pattern damage threshold, axial non-uniformity, axial non-
uniformity threshold, grid non-uniformity, grid non-uniformity threshold,
unused ECC, unused ECC threshold>
Disabled
0 = Disabled
1 = Enabled
1 = Enabled