Timeout and New Trigger
Usage:
Definition:
Last Frame
Usage:
Definition:
Last Frame / New Trigger
Usage:
Definition:
F-9-2
Read Cycle Timeout
Definition:
Serial Cmd:
Default:
Options:
F-14
Useful in applications that require an alternative way to end the read
cycle. For example, if an assembly line should stop completely or the
intervals between objects are highly irregular.
Timeout or New Trigger is identical to Timeout except that a timeout or a
new trigger (whichever occurs first) ends the read cycle.
Useful in applications in which the number of captures needed can be
defined but the timeout duration varies.
Last Frame only applies to Rapid Capture Mode.
Useful in applications in which line speeds are irregular and a new
labelled object could appear before the last frame in a Rapid Capture
sequence.
Last Frame or New Trigger is identical to New Trigger except that a new
trigger or last frame (whichever occurs first) ends the read cycle.
Read Cycle Timeout is the duration of the read cycle.
<K220,end of read cycle,read cycle timeout>
100 (x10 ms)
1 to 65535
V440-F C-Mount Code Reader User Manual