Sequence Step Interval - Omron V440-F User Manual

C-mount code reader
Table of Contents

Advertisement

J-4

Sequence Step Interval

Usage:
Definition:
Serial Cmd:
Default:
Options:
Example: If Sequence Step is set to 3 and Sequential Matching is set to Increment:
Master Symbol
003
003
003
006
006
006
V440-F C-Mount Code Reader User Manual
Useful in applications in which it is desirable to count by intervals other
than 1.
Sequencing in Matchcode operations can occur in steps from 1 to
32,768.
Sequencing performs like a mechanical counter by displaying positive
integers and a specific number of digits after roll-overs. For example, 000
– 3 = 997 (not -3) and 999 + 3 = 002 (not 1002).
<K228,sequence step interval>
1
Any number from 1 to 32768.
Decoded Symbol
001
002
003
004
005
006
Master Symbol after Decode
003
003
006
006
006
009