Omron V440-F User Manual page 75

C-mount code reader
Table of Contents

Advertisement

4 Setup
4-3-4-1 – Triggered with Capture Mode = Continuous
Triggered with Capture Mode = Continuous is useful in motion applications with slower line speeds
or where symbol position or spacing may be random or not time-dependent. The read cycle starts with
a trigger. An initial Burst of Captures is taken. The reader begins processing the first captured image
and extracts a decode while at the same time it captures the second image. The reader will then
continuously take another capture after every decode until all symbols are found, until the timeout is
reached, or until a new trigger is received.
• Serial Trigger Character – Sets the serial input trigger character. The reader will also respond to an
edge change on the physical trigger input.
• Trigger Before 1st Capture– This is the amount of time between when the trigger is received and
when the reader takes the first picture. This is useful for adjusting code position on a moving line.
• Capture Mode = Continuous – The reader will continuously acquire and process images. Acquisition
and processing are overlapped.
• Number of Burst Captures – This is the number of initial captures the reader will take at the start of
the read cycle before waiting for a decode, at which time the reader will take another capture. Number
of Burst Captures can be found in Advanced Settings > Read Cycle.
4-12
V440-F C-Mount Code Reader User Manual

Advertisement