Omron V440-F User Manual page 345

C-mount code reader
Table of Contents

Advertisement

Appendices
Diagnostic Warning
Usage:
Definition:
In Read Cycle
Definition:
H-6-1
Output State
Definition:
Serial Cmd:
Default:
Options:
H-6-2
Pulse Width
Definition:
Serial Cmd:
Default:
Options:
H-6-3
Output Mode
Definition:
Serial Cmd:
Default:
Options:
Pulse
This is the default mode of operation in which the programmable output is activated when the Output
On condition has been met and held active for the duration of the selected pulse width.
Latch Mode 2 (Unlatch Opposite Condition)
The programmable output is activated when the Output On condition has been met and held active
until the opposite condition selected under Output On has been met.
For example, if No-Read is enabled under Output On, the programmable output will go active on a No-
Read and remain active until the opposite condition, a good read, occurs.
Latch Mode 3 (Unlatch Re-enter Read Cycle)
The programmable output is active when the Output On condition has been met and is held active until
a new read cycle begins.
• Note: All of the Output On modes are inhibited when any Output on Warning is active for Output 1.
H-10
Typically used when a discrete indication of a diagnostic condition is needed.
Activates discrete output when a diagnostic warning condition is met,
depending on the diagnostic option enabled.
Activates a discrete output when the reader is in a read cycle.
Sets the active electrical state of the discrete output.
<K810,output on,output state,pulse width,output mode>
Normally Open
0 = Normally Open
Sets the time in 1 ms increments that the discrete output remains active.
<K810,output on,output state,pulse width,output mode>
500ms
0 to 65535(in 1 ms increments)
Sets the condition in which the discrete output is de-activated.
<K810,output on,output state,pulse width,output mode>
Pulse
0 = Pulse
2 = Latch Mode 2
3 = Latch Mode 3
1 = Normally Closed