Camera Settings - Omron V440-F User Manual

C-mount code reader
Table of Contents

Advertisement

Appendices
K-4 Camera Settings
Camera Settings are typically obtained during the calibration process, and do not necessarily need to
be modified directly by the user.
K-4-1
QSXGA, SXGA, and WVGA
 Exposure
Usage:
Definition:
Serial Cmd:
Default:
Options:
 Gain
Usage:
Definition:
Serial Cmd:
Default:
Options:
K-6
Faster exposures reduce blurring in faster applications.
Slower exposures are useful in slower applications and lower contrast
applications.
This value sets the exposure or integration time (in microseconds) for the
image sensor pixels. The exposure setting in relation to the speed of the
object is critical. If an object is moving rapidly and too long an exposure
value is selected, blurring or smearing of the object will occur. As exposure
time is decreased the movement of the object becomes less of a factor but,
with the duration of light collection by the pixels reduced, the image sensor
gain will need to be increased to compensate.
<K541,exposure,gain>
All versions: 1000 μs
Any number between 16 – 400,000
Can be used to adjust the brightness of the image.
Sets the gain value for the image sensor and is a percentage value from
0 (lowest gain) to 100% (highest gain). This setting can be configured
through autocalibration. A higher gain value will increase the brightness
of the image, but the noise performance of the system will be reduced.
Before configuring the gain, the required exposure should be set, and the
gain should be configured to optimize the exposure setting.
<K541,exposure,gain>
0
Any number between 0 – 100, representing 0% to 100%
Gain is set in 1% increments.
V440-F C-Mount Code Reader User Manual

Advertisement

Table of Contents
loading

Table of Contents