Appendix J Matchcode; Matchcode - Omron V440-F User Manual

C-mount code reader
Table of Contents

Advertisement

Appendices
J-3

Matchcode

Definition:
Serial Cmd:
Default:
Options:
Disabled:
Enabled:
Wildcard:
Sequential:
J-3-1
Sequential Matching
Usage:
Definition:
Serial Cmd:
Default:
Options:
J-3-2
Match Start Position
Usage:
Definition:
Function:
Serial Cmd:
Default:
Options:
Note: Match Start Position must be set to 1 or greater to enable this feature. 0 disables this feature.
J-4
Allows you to choose the way that master symbols will be compared with
subsequently read symbols.
Note: First set Triggering Mode to External or Serial.
<K223,matchcode,sequential matching,match start position, match
length,wildcard,sequence on No Read,sequence on mismatch,placeholder
character>
Disabled
0 = Disabled
1 = Enabled
2 = Wildcard
3 = Sequential
Has no effect on operations.
Instructs the reader to compare symbols or portions of symbols with the
master symbol.
Allows the user to enter user-defined wildcard characters in the master
symbol.
Instructs the reader to sequence after each match (numeric only) and
compare symbols or portions of symbols for sequential numbers.
Note: If Matchcode Type is set to Sequential, the reader will behave
as if Number of Symbols were set to 1, regardless of the user-defined
configuration.
Useful in tracking product serial numbers that increment or decrement
sequentially.
With Sequential enabled, Sequential Matching determines if a count is
in ascending (incremental) or descending (decremental) order.
<K223,matchcode,sequential matching,match start position,match
length,wildcard,sequence on No Read,sequence on mismatch,placeholder
character>
Increment
0 = Increment
Match Start Position is useful in defining specific portions of a symbol
for comparison. For example, if a symbol contains a part number, manufacturing
date, and lot code info, but you are only interested in the part number
information, you can set the reader to sort only the part number and
ignore the other characters.
Match Start Position determines the portions of symbols that will be
matched by defining the first character in the symbol (from left to right)
that will be compared with those of the master symbol, when Matchcode
Type is set to Enabled or Sequential.
For example, if Match Start Position is set to 3, the first 2 characters
read in the symbol will be ignored and only the 3rd and subsequent
characters to the right will be compared, up to the number of characters
specified by Match Length.
<K223,matchcode,sequential matching,match start position, match
length,wildcard,sequence on No Read,sequence on mismatch,placeholder
character>
0
0 to 3000
1 = Decrement
V440-F C-Mount Code Reader User Manual

Advertisement

Table of Contents
loading

Table of Contents