Global Sorting Options - Omron V440-F User Manual

C-mount code reader
Table of Contents

Advertisement

Appendices
N-8 Global Sorting Options
Note: Regular Output Filter, <K743>, will take precedence over this option if it is enabled. Decode
output will follow Output Filter rules.
Note: Although this feature has built in tolerance when one symbol not exactly line up with other
symbols on the image to consider as same row or column, it is best to be used when the image has
single row or column of symbol to decode or output.
Global Sorting Options specifies the sorting that a user wants to apply to the global
Definition:
matrix or to decoded symbol output.
Serial Cmd: <K748,sort output,row direction,column direction,minimum same-row symbol overlap
height percentage,minimum same-column symbol overlap width percentage>
N-8-1
Sort Output
Allows you to order symbol data output by row or by column.
Definition:
Serial Cmd: <K748,sort output,row direction,column direction,minimum same-row symbol overlap
height percentage,minimum same-column symbol overlap width percentage>
Default:
0 = Disabled
Options:
0 = Disabled
N-8-2
Row Direction
Allows you to determine which direction decoded symbol data should be output in a row setup.
Definition:
Serial Cmd: <K748,sort output,row direction,column direction,minimum same-row symbol overlap
height percentage,minimum same-column symbol overlap width percentage>
Default:
0 = Left to Right
Options:
0 = Left to Right
N-8-3
Column Direction
Allows you to determine which direction decoded symbol data should be output in a
Definition:
column setup.
Serial Cmd: <K748,sort output,row direction,column direction,minimum same-row symbol overlap
height percentage,minimum same-column symbol overlap width percentage>
Default:
0 = Top to Bottom
Options:
0 = Top to Bottom
N-8-4
Minimum Same-Row Symbol Overlap Height Percentage
Allows you to determine the minimum percentage of overlap at which two symbols are
Definition:
considered to be on the same row.
Serial Cmd: <K748,sort output,row direction,column direction,minimum same-row symbol overlap
height percentage,minimum same-column symbol overlap width percentage>
Default:
20
Any number from 0 to 100 (0 = 0% and 100 = 100%)
Options:
Example:
N-10
1 = By Row
1 = Right to Left
1 = Bottom to Top
Symbol B is part of R1 if Minimum Same-Row Symbol
Overlap Height Percentage is set to 20.
2 = By Column
V440-F C-Mount Code Reader User Manual