A --20 Appendix
We can get a history of what the unequipped line detection feature has reported
by dumping the AUDT202 logs out of the DMS. This shows us when the line
state changed from IDL to LMB and from LMB back to IDL.
>
> logutil
Current MODE setting is: EXTENDED
LOGUTIL:
> open audt
Done.
RTPE13BH
LINE_EQUIPMENT_NUMBER ERCS
FROM
> back
RTPE13BH
LINE_EQUIPMENT_NUMBER ERCS
FROM
> ?
>back
RTPE13BH
LINE_EQUIPMENT_NUMBER ERCS
FROM
> ?
>back
RTPE13BH
LINE_EQUIPMENT_NUMBER ERCS
FROM
> ?
>back
RTPE13BH
LINE_EQUIPMENT_NUMBER ERCS
FROM
> ?
>back
RTPE13BH
LINE_EQUIPMENT_NUMBER ERCS
FROM
>
OPEN WRITING XPMTLC0001SMS.AA02 2000/04/13 11:31:50
AUDT202 JAN31 14:57:45 2600 INFO LINE AUDIT
00 0 00 01
LINE_LM_BUSY TO
AUDT202 JAN31 14:54:45 7100 INFO LINE AUDIT
00 0 00 00
LINE_LM_BUSY TO
AUDT202 JAN31 14:53:15 5400 INFO LINE AUDIT
00 0 00 01
LINE_IDLE TO
AUDT202 JAN31 14:53:15 5300 INFO LINE AUDIT
00 0 00 00
LINE_IDLE TO
AUDT202 JAN31 14:50:15 8700 INFO LINE AUDIT
00 0 00 01
LINE_LM_BUSY TO
AUDT202 JAN31 14:50:15 8600 INFO LINE AUDIT
00 0 00 00
LINE_LM_BUSY TO
LINE_IDLE
LINE_IDLE
LINE_LM_BUSY
LINE_LM_BUSY
LINE_IDLE
LINE_IDLE