5-6 Recovery procedures
Recovering
an SMS
(continued)
4
5
297-8231-550 Standard 09.01 August 1998
CAUTION
LOCAL IMAGE cannot load ISDN units
Do not LOADPM from the LOCAL IMAGE on units
with ISDN capability. The NT7X05 card does not
support ISDN. Use LOCAL LOADFILE or load from
the central control (CC) on units with ISDN.
To load the SMS from the local image, type
>LOADPM PM LOCAL IMAGE
and press the Enter key.
If the load
passes
fails
WARNING
Possible service interruption
The LOCAL LOADFILE option of the LOADPM
command has a parameter of [<file> string}]. If you
use this file_name parameter, use the loadfile named
in the parameter. The loadfile named in the parameter
is not patched. Only use this parameter when you
need the NOPATCH option of the loadfile.
To load the SMS from the local loadfile, type
>LOADPM PM LOCAL LOADFILE
and press the Enter key.
If the load
passes
fails
Do
step 7
step 5
Do
step 7
step 6