6-14 Alarm clearing procedures
PM SMS
major
(continued)
21
22
23
24
25
26
27
297-8231-550 Standard 09.01 August 1998
To eave table LTCINV, type
>QUIT
and press the Enter key.
Perform the procedure Updating static data from Alarm Clearing Procedures .
When you complete this procedure, go to step 23.
To check for fault indicators, type
>QUERYPM FLT
and press the Enter key.
If PM load mismatch with CC
appears again
does not appear again
To display the C-side link information, type
>TRNSL C
and press the Enter key.
For additional help, contact the personnel responsible for network maintenance
support.
To manually busy the inactive unit, type
>BSY UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the inactive unit
To test the inactive unit, type
>TST UNIT unit_no
and press the Enter key.
where
Do
step 37
step 38