To return the inactive unit to service, type
>RTS UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the inactive unit
If the message
passes
fails
5
CAUTION
Service disruption. The PM can drop calls.
If the system prompts you to confirm a cold SWACT,
perform this activity in a period of low traffic. The
PM will end all calls, including data calls.
To switch the activity of the units, type
>SWACT
and press the Enter key.
The system determines the type of SWACT (warm or cold) that the system can
perform. The system displays a confirmation prompt for the selected SWACT.
If the SWACT
cannot continue at this time
can continue at this time
6
Do not switch activity of the units. To reject the switch, type
>NO
and press the Enter key.
The system discontinues the switch of activity. Return to step 5 in a period of
low traffic.
DMS-100 Family SMS Maintenance Manual XPM10 and up
Alarm clearing procedures 6-9
major
(continued)
Do
step 38
step 37
Do
step 6
step 7