Nortel DMS-100 Series Maintenance Manual page 199

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

where
link_no
is the number of the link tested in step 33.
If RTS
passes
fails
44
Determine if additional SysB links are present.
If additional SysB links
are present
are not present
45
For additional help to clear this alarm contact the next level support.
46
You returned the inactive unit to service. Determine if the active unit is
in-service.
If active unit is
InSv
ISTb
47
CAUTION
Service disruption.
If the system prompts you to confirm a cold SWACT,
perform this activity only during a period of low
traffic. The system drops all calls that this PM
handles including data calls.
To switch the activity of the units, type
>SWACT
and press the Enter key.
DMS-100 Family SMS Maintenance Manual XPM10 and up
Alarm clearing procedures 6-35
minor
(continued)
Do
step 44
step 45
Do
step 39
step 46
Do
step 52
step 47
PM SMS

Advertisement

Table of Contents
loading

Table of Contents