7-140 Card replacement procedures
NTMX77
NTMX77
SMS
SMS
(end)
(continued)
24
25
26
27
28
29
30
297-8231-550 Standard 09.01 August 1998
Return the inactive SMS unit to service by typing
>RTS UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the faulty SMS unit tested in step 23
If RTS
passes
fails
Send any faulty cards for repair according to local procedure.
Remove the sign from the active SMS unit.
Record the following items in office records according to local policy:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue as
directed.
Obtain further assistance in replacing this card by contacting personnel
responsible for a higher level of support.
For further assistance with switch of activity, contact the personnel responsible
for the next level of support.
Note: If the system recommends using the SWACT command with the FORCE
option, consult office personnel to determine if use of the FORCE option is
advisable.
Do
step 25
step 29