Use the following information to determine what step to go to next in this
procedure.
If you entered this procedure
from
alarm clearing procedures
other
15
Test the inactive unit by typing
>TST UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the faulty SMS unit
If TST
passed
failed
16
Return the inactive SMS unit to service by typing
>RTS UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the faulty SMS unit
If RTS
passed
failed
17
Return to the maintenance procedure that directed you to this procedure. At the
point where a faulty card list was produced, identify the next faulty card on the
list and go to the appropriate card replacement procedure for that card in this
manual.
DMS-100 Family SMS Maintenance Manual XPM10 and up
Card replacement procedures 7-45
SMS
Do
step 17
step 15
Do
step 16
step 17
Do
step 19
step 18