Nortel DMS-100 Series Maintenance Manual page 223

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT6X40 in a SMS
At your current location
1
Proceed only if you have been directed to this card replacement procedure from
a step in a maintenance procedure, are using the procedure for verifying or
accepting cards, or have been directed to this procedure by your maintenance
support group.
2
CAUTION
Loss of service
When replacing a card in the SMS, ensure the unit in
which you are replacing the card is inactive and the
mate unit is active.
Obtain an NT6X40 replacement circuit card. Ensure the replacement circuit
card has the same product engineering code (PEC), including suffix, as the
circuit card being removed.
At the MAP terminal
3
Access the peripheral module (PM) level of the MAP display and post the SMS
with the faulty card by typing
>MAPCI;MTC;PM;POST SMS sms_no
and pressing the Enter key.
where
sms_no
is the PM number (0 to 255)
Example of a MAP response:
SMS
0 Quit
PM
2 Post_
SMS
3 ListSet
4
SMS
5 TRNSL
Unit0:
6 TST
Unit1:
7 BSY
8 RTS
9 OffL
10 LoadPM_
11 Disp_
12 Next_
SysB
ManB
OffL
0
0
0
0
0 ISTb
Links_OOS:
Inact ISTb
Act InSv
DMS-100 Family SMS Maintenance Manual XPM10 and up
Card replacement procedures 7-17
in a SMS
CBsy
ISTb
2
0
2
0
0
1
CSide
1, PSide
1
NT6X40
(continued)
InSv
25
1

Advertisement

Table of Contents
loading

Table of Contents