Nortel DMS-100 Series Maintenance Manual page 192

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-28 Alarm clearing procedures
PM SMS
minor
(continued)
16
17
18
19
20
297-8231-550 Standard 09.01 August 1998
To return the inactive unit to service, type
>RTS UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the inactive unit
If RTS
passes
fails
Perform the procedure, "Updating static data". Refer to common procedures to
clear an alarm. When you return to this procedure, go to step 18.
Determine if the system cleared ISTb fault.
If ISTb fault
clears
does not clear
To determine the load that the SMS that has defects must use, type
>QUERYPM CNTRS
and press the Enter key.
Example of a MAP response:
UNSOLICITED MSG LIMIT = 250, UNIT0 = 0, UNIT1 = 0
UNIT 0:
RAM LOAD:
SU33BF
ROM LOAD:
SMSRFA10
UNIT 1:
RAM LOAD:
SU33BF
ROM LOAD:
SMSRFA10
To access Table LTCINV, type
>TABLE LTCINV
and press the Enter key.
Do
step 46
step 45
Do
step 46
step 45