Nortel DMS-100 Series Maintenance Manual page 312

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-106 Card replacement procedures
NT6X92
SMS
(continued)
14
15
16
17
18
297-8231-550 Standard 09.01 August 1998
Use the following information to determine where to go next in this procedure.
If you entered this procedure
from
alarm clearing procedures
other
Test the inactive unit by typing
>TST UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the faulty SMS unit
If TST
passed
failed
Return the inactive SMS unit to service by typing
>RTS UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the faulty SMS unit
If RTS
passed
failed
Return to the Alarm Clearing Procedures that directed you to this procedure. At
the point where a faulty card list was produced, identify the next faulty card on
the list and go to the appropriate card replacement procedure for that card in
this manual.
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
Do
step 17
step 15
Do
step 16
step 17
Do
step 19
step 18