Nortel DMS-100 Series Maintenance Manual page 224

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-18 Card replacement procedures
NT6X40
in a SMS
(continued)
4
5
6
297-8231-550 Standard 09.01 August 1998
Determine the location of the SMS containing the NT6X40 circuit card you are
replacing by typing
>QUERYPM
and pressing the Enter key.
Example of a MAP response:
QueryPM
PM Type: SMS
PMs Equipped: 139 Loadname: NSS05BC
WARM SWACT is supported and available.
SMS 0 is included in the REX schedule.
REX on SMS 0 has not been performed.
Node Status: {OK, FALSE}
Unit 0
Act, Status: {OK, FALSE}
Unit 1 Inact, Status: {OK, FALSE}
Site Flr RPos
HOST
01
E31
Determine the state and activity of the XPM unit in which the card you replacing
is provisioned.
If the state of the PM unit is
ISTb, InSv, SysB, or CBsy, and
active
ISTb, InSv, SysB, or CBsy, and
inactive
ManB
OffL
From the MAP display, determine the state of the mate PM unit.
If the SMS unit is
ISTb or InSv
any other state
PM No.: 0
PM Int. No.:11 Node_No.: 192
Bay_id
Shf Description Slot EqPEC
SME
01
18
Do
step 6
step 9
step 9
step 33
Do
step 7
step 35
SMS :
000
6X02AA

Advertisement

Table of Contents
loading

Table of Contents