6-40 Alarm clearing common procedures
Updating static data
XPM
(continued)
Updating static data in an XPM
At the MAP terminal:
1
2
3
297-8231-550 Standard 09.01 August 1998
Proceed only if a step in a maintenance procedure directed you to this
procedure. Independent use of this procedure can cause equipment damage
or loss of service.
To busy the inactive unit, type
>BSY UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the inactive unit
CAUTION
Loss of service
All calls that this PM handles, including data calls,
will be lost. Perform the next step during a period of
low traffic only.
To return the inactive unit to service, type
>RTS UNIT unit_no NODATASYNC
and press the Enter key.
where
unit_no
is the number of the inactive unit