Nortel DMS-100 Series Maintenance Manual page 177

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

17
To access table LTCINV, type
>TABLE LTCINV
and press the Enter key.
18
To position on the tuple for the SMS that has defects, type
>POS SMS sms_no
and press the Enter key.
where
sms_no
is the number of the SMS that has defects
19
To change the load name, type
>CHA LOAD
and press the Enter key.
Example of a MAP response:
LOAD:
SU33BE
20
To enter the correct load name, type
>load_name
and press the Enter key.
where
load_name
is the load name from step 16
Example of a MAP response:
TUPLE TO BE CHANGED:
SMS 0
SME
0
NORTHAM
6X40AC
ENTER Y TO CONFIRM, N TO REJECT, OR E TO EDIT.
For a positive response to the confirmation request, type;
>Y
and press the Enter key.
32
0
C
1
6X02AA
( 0 40) ( 0 42) ( 1 40) ( 0 30)$
( MSG6X69 )
(
MX77AA
MX77AA
DMS-100 Family SMS Maintenance Manual XPM10 and up
Alarm clearing procedures 6-13
major
SU33BF
(POTS POTSEX)$
CMR16 CMRAB02) $
$
PM SMS
(continued)

Advertisement

Table of Contents
loading